Installing PTFs for VSM GUI
This chapter describes how to install the corrective service PTFs for VSM GUI, which 
you can download from the Sun StorageTek Customer Resource Center at:
http://www.support.storagetek.com.
Note – 
Before you install PTFs, you must install VSM GUI as described in “Installing 
For information on accessing the CRC, see “Customer Resource Center” on page xii
Installing the PTFs
After you have downloaded the desired PTFs from the StorageTek CRC, install them 
using the following procedure:
1. Ensure that you have customized the installation jobs as described in “Set Up the 
2. If necessary, modify member 
V1RCV
.
Change the 
SMPPTFIN
 and 
SMPHOLD 
DDs to point to the downloaded data set names. If 
there was no 
HOLDDATA
 downloaded, then remove the 
SMPHOLD
 DD and only receive 
SYSMODS
.
3. Run member 
V1RCV
 to 
RECEIVE
 the VSM GUI PTFs. 
4. If necessary, modify member 
V2APPLY
Before running the apply job, review the output from the receive job for 
HOLDDATA
, and 
follow the instructions given for each held PTF. When the requirements are met, bypass 
the hold condition for that held PTF in the apply job with the 
BYPASS
 parameter. Do not 
bypass 
HOLDERROR
 conditions. 
5. Run member 
V2APPLY
 to 
APPLY
 the VSM GUI PTFs.