Справочник Пользователя для Hitachi HDS721032CLA362

Скачать
Страница из 258
Hitachi hard disk drive specifications   
47 
General 
7.1  Introduction 
This  specification  describes  the  host  interface  of  HDS7210xxCLA3yz  /  HUA7220xxCLA33z  / 
HCS5C10xxCLA382 / HCS7210xxCLA3y2 
HDS5C10xxCLA382
 
The  interface  conforms  to  the  following  working  documents  of  Information  technology  with  certain  limitations 
described in the chapter 0 
“Deviations from Standard” on page 47   
–  Serial ATA II: Extensions to Serial ATA Revision 2.6 
 
7.2  Terminology 
Device
 
Device indicates    HDS7210xxCLA3yz / HUA7220xxCLA33z / 
HCS5C10xxCLA382 / HCS7210xxCLA3y2 
HDS5C10xxCLA382 
Host
 
Host indicates the system that the device is attached to.
 
 
7.3  Deviations From Standard 
The device conforms to the referenced specifications, with deviations described below. 
Check Power Mode
 
Check  Power  Mode  command  returns  FFh  to  Sector  Count  Register  when  the 
device is in Idle mode. This command does not support 80h as the return value
.
 
COMRESET
 
COMRESET response is not the same as that of Power On Reset.    Refer to 
section 5.1, 
“Reset Response” for detail. 
Download
 
Download command is aborted when the device is in security locked mode. 
COMRESET response time
  During 500ms from Power On Reset, COMINIT is not returned within 10ms as a 
response to COMRESET. 
Streaming Commands
 
When the device is in standby mode, 
Streaming Commands can‟t be completed 
while waiting for the spindle to reach operating speed even if execution time 
exceeds specified CCTL(Command Completion Time Limit). The minimum CCTL 
is 50ms.CCTL is set to 50ms when the specified value is shorter than 50ms. For 
HCS7210xxCLA3y2 and HCS5C10xxCLA382, the minimum CCTL is 100ms. 
Error Recover Control 
(SCT Command set)
 
When the device is in standby mode, any command where error recovery time 
limit is sp
ecified can‟t be completed while waiting for the spindle to reach operating 
speed even if execution time exceeds specified recovery time limit. The minimum 
time limit is 6.5 second. When the specified time limit is shorter than 6.5 second, 
the issued command is aborted. For HCS7210xxCLA3y2 and 
HCS5C10xxCLA382, the minimum time limit is 0.3 second.