Справочник Пользователя для Hitachi HDS721075CLA632

Скачать
Страница из 258
Hitachi hard disk drive specifications   
206 
11.42.1.4 
SMART Save Attribute Values (Subcommand D3h) 
This subcommand causes the device to immediately save any updated Attribute 
Values to the device‟s Attribute 
Data sector regardless of the state of the Attribute Autosave feature. Upon receipt of the SMART Save Attribute 
Values subcommand from the host, the device writes any updated Attribute Values to the Attribute Data sector. 
11.42.1.5 
SMART Execute Off-line Immediate (Subcommand D4h) 
This subcommand causes the device to immediately initiate the set of activities that collect Attribute data in an 
off-line mode (off-line routine) or execute a self-test routine in either captive or off-line mode. 
The Sector Number register shall be set to specify the operation to be executed. 
Sector Number    Operation to be executed 
Execute SMART off-line data collection routine immediately 
Execute SMART Short self-test routine immediately in off-line mode 
Execute SMART Extended self-test routine immediately in off-line mode 
4 
Execute SMART Selective self-test routine immediately in off-line mode 
127 
Abort off-line mode self-test routine 
129 
Execute SMART Short self-test routine immediately in captive mode 
130 
Execute SMART Extended self-test routine immediately in captive mode 
132 
Execute SMART Selective self-test routine immediately in captive mode 
 
Off-line  mode:  The  device  executes  command  completion  before  executing  the  specified  routine.  During 
execution of the routine the device will not set BSY nor clear DRDY. If the device is in the process of performing 
its routine and is interrupted by a new command from the host, the device will abort or suspend its routine and 
service the host within two seconds after receipt of the new command. After servicing the interrupting command, 
the device will resume its routine automatically or not start its routine depending on the interrupting command. 
Captive  mode:  When  executing  self-test  in  captive  mode,  the  device  sets  BSY  to  one  and  executes  the 
specified self-test routine after receipt of the command. At the end of the routine, the device sets the execution 
result in the Self-test execution status byte (0) and ATA registers as below and executes command completion. 
Status 
Set ERR to one when self-test has failed 
Error 
Set ABRT to one when self-test has failed 
Cyl Low 
Set to F4h when self-test has failed 
Cyl High 
Set to 2Ch when self-test has failed