11.37  Sense Condition (F0h : Vendor specific for Cinemastar)
 
 
Command Block Output Registers
 
 
Command Block Input Registers
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
Data
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Data
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Feature
 
0  0  0  0  0  0  1 
 
Error
 
…See Below…
 
Sector Count
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Sector Count
 
V  V 
V  V  V 
V  V 
Sector Number
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Sector Number
 
Cylinder Low
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Cylinder Low
 
Cylinder High
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Cylinder High
 
Device/Head
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Device/Head
 
Command
 
1  1  1  0  0  0  0 
 
Status
 
…See Below…
 
 
 
Error Register
 
 
Status Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
CRC
 
UNC
 
0
 
IDN
 
0
 
ABT
 
T0N
 
AMN
 
 
BSY
 
RDY
 
DF
 
DSC
 
DRQ
 
COR
 
IDX
 
ERR
 
0
 
0
 
0
 
0
 
0
 
V
 
0
 
0
 
 
Table 138    Sense Condition command (F0h) 
The Sense Condition command is used to sense temperature in a device.   
 
This command is executable even if a device is in Power up in standby mode. 
 
Output Parameters To The Device 
Feature 
The Feature register must be set to 01h. All other value are rejected 
with setting ABORT bit in status register. 
Input Parameters From The Device 
Sector Count 
The Sector Count register contains result value. 
 
Value 
Description 
 
00h 
Temperature is equal to or lower than -20 degC 
 
01h-FEh 
Temperature is (Value / 2 - 20) deg C 
 
FFh 
Temperature is higher than 107 degC