SECTION 16 
FAULT PROTECTION 
 
The IM481H is internally protected against over temperature, and over current. 
 
The over temperature set point is between 60 and 70 °C.  Care should be taken when 
choosing and installing a heat sink so that there is a good thermal conduction, otherwise 
hot spots may occur in the IM481H which will reduce the operating thermal range. 
 
The over current protection consists of PHASE to PHASE, and +V to PHASE. 
 
If an output driver in the IM481H detects an over temperature condition it will shut down 
but will not activate the fault output. Once the temperature drops to a safe operating 
temperature, the IM481H will resume operation. 
 
If an over current fault is detected  by the IM481H, the outputs will be disabled and cannot 
be re-enabled without resetting the driver or by cycling power. At the same time the active 
high FAULT output (pin 19) is enabled. 
 
The FAULT IN input (pin 6) can be used to force a fault condition. When pulled low the 
signal is latched and the outputs will be disabled. The fault condition can only be cleared 
by cycling power or resetting the driver. 
 
 
 
 
SECTION 17 
THERMAL REQUIREMENTS 
 
The IM481H may require heat sinking to maintain a safe operating temperature. Care 
should be taken when mounting the IM481H to a heat sink with an electrically conductive 
surface that an isolating thermal pad is used.
 
 
 
 
 
 
 
 
 
NOTE:
 
 
 
The watts dissipated by the IM481H can be calculated as follows: 
 
Watts Dissipated = ( 0.6 x ( Peak per Phase Output Current )
2
 )  
 
EXAMPLE:  Peak per Phase Output Current = 1.4 amps 
 
                                Watts Dissipated = 1.18 
20
 
W A R N I N G ! Rear mounting surface of driver contains 
different voltages and must be kept isolated when attached 
to a conductive surface ! 
An optional  thermal pad ( Part # TI-481 ) and heat sink ( Part # H-481 ) is available 
for the IM481H