Справочник Пользователя для National Instruments 321042A-01

Скачать
Страница из 53
Chapter 4
Installation Verifica tion and Troubleshooting
© National Instruments Corp.
4-3
STD-GPIB for Windows
Correcting Hardware Settings
Follow these steps to troubleshoot Hardware Diagnostic Test error messages.
1.
Make sure you are using a valid base I/O address.
Run the Hardware Diagnostic Test again.  When it prompts you for values, enter
your base I/O address, but enter <N> for both the interrupt request line and the DMA
channel.  If the test fails again, one of the following situations is occurring:
The base address that you entered when prompted does not match the switch
settings of the STD-GPIB.  Check the switch settings again.
Another module or built-in device in your system is using the same address
space.  Change the base I/O address of your STD-GPIB and repeat this step
using the new setting.
The module is defective or cannot operate in your system.  Complete the
Technical Support Form  in Appendix C,  Customer Communication, and contact
National Instruments.
2.
Make sure you are using a valid interrupt request line.
Run the Hardware Diagnostic Test again.  When it prompts you for values, enter the
valid base I/O address as determined in Step 1, the interrupt request line, and <N>
for the DMA channel.  If the test fails, one of the following situations is occurring:
The interrupt request line that you entered when prompted does not match the
jumper setting of the STD-GPIB.  Check the jumper setting again.  If you are
using a computer not manufactured by either Ziatech or WinSystems, refer to
Appendix B,  Interrupt Routing, for proper interrupt jumper settings.
Another module or built-in device in your system is using the same interrupt
request line.  Change the interrupt request line of the STD-GPIB and repeat this
step using the new setting.
The module is defective or cannot operate in your system.  Complete the
Technical Support Form in Appendix C, Customer Communication, and contact
National Instruments.