Справочник Пользователя для Dialogic 05-2548-006

Скачать
Страница из 44
Dialogic
®
 Multimedia Software for ATCA Release 1.0 Release Update, Rev 06 — January 23, 2008
17
Dialogic Corporation
Resolved
IPY00035425
77
PSTN call control
The firmware is printing unnecessary logs to the 
messages file. These messages can be ignored.
The messages are similar to the following:
Oct 19 11:10:31 py1atcatvl16 CLIAGENT: From 
Component: IPMS_ShowLinkAlarm : @         
LastChange:0 seconds @ 
Oct 19 11:13:22 py1atcatvl16 ssp_x86Linux_boot: line 
3056, file src/c/tsccomp.c 
Oct 19 11:13:22 py1atcatvl16 ssp_x86Linux_boot: line 
1198, file src/c/tsccomp.c 
Oct 19 11:13:22 py1atcatvl16 ssp_x86Linux_boot: line 
3056, file src/c/tsccomp.c 
Oct 19 11:13:22 py1atcatvl16 ssp_x86Linux_boot: line 
1198, file src/c/tsccomp.c 
Oct 19 11:13:22 py1atcatvl16 [0xffff0000]TSC.000 
Received unexpected message Unknown message 
type(0x1244) from 0:0:2:b [0xffff0000]TSC.001 
Received unexpected message Unknown message 
type(0x1234) from 0:0:2:b [0xffff0000]TSC.000 
Received unexpected message Unknown message 
type(0x1244) from 0:0:2:b [0xffff0000]TSC.032 
Received unexpected message Unknown message 
type(0x1234) from 0:0:2:b 
Oct 19 11:14:47 py1atcatvl16 ssp_x86Linux_boot: 
RtcWriteBEvtDetected error: Event type -4605 is out of 
range (max=127) 
Resolved
IPY00034277
--
TDM bus
Receive failures in the DS1 adapter when attempting to 
add a clock source to the FallBackList table via SNMP. 
The Clock FallBack List is not functional; the user can 
choose a clock but will not be able to rely on a fallback 
list.
Resolved
IPY00034275
--
TDM bus
When no fallback list is present, the TDM clock 
manager in the firmware will attempt to access the non-
existent list when the cable is unplugged from a PSTN 
trunk. This causes two identical events to be forwarded 
to the CLI and SNMP saying that the TDM clock has 
changed sources twice. This is misleading because in 
actuality the clock source has not changed and red 
alarms on a particular trunk (or trunks) should not have 
any effect on the default internal oscillator clock source.
The Clock FallBack List is not functional; the user can 
choose a clock but will not be able to rely on a fallback 
list.
Resolved
IPY00033580
--
third party support
Using RFC2833 with coder type G723.1 63(56)K, 
30ms, 1(2) fpp, VAD off, digits are missed at a rate of 1 
to 2%. (An example of missing digits is received 
“19d6a*”, expected “159d86a*”.)
Issues Sorted by Type, Dialogic
®
 Multimedia Platform (Continued)
Issue Type
Defect No.
SU 
No.
Product or 
Component
Description