Chapter 2. CLI Syntax Reference
48
3ware Serial ATA RAID Controller CLI Guide 
 --------------------------------------------------------------------------
 u0    RAID-5    INITIALIZING  0       -       64K     521.466   ON     OFF
 Port   Status           Unit   Size        Blocks        Serial
 ---------------------------------------------------------------
 p0     NOT-PRESENT      -      -           -             -
 p1     OK               u0     76.33 GB    160086528     Y2NXL7FE
 p2     NOT-PRESENT      -      -           -             -
 p3     OK               u0     76.33 GB    160086528     Y2NXLB9E
 p4     NOT-PRESENT      -      -           -             -
 p5     OK               u0     76.33 GB    160086528     Y2NXQPZE
 p6     NOT-PRESENT      -      -           -             -
 p7     OK               u0     76.33 GB    160086528     Y2NXM4VE
 p8     OK               u0     74.53 GB    156301488     3JV3WTSE
 p9     OK               u0     74.53 GB    156301488     3JV3WRHC
 p10    OK               u0     74.53 GB    156301488     3JV3WQLQ
 p11    OK               u0     74.53 GB    156301488     3JV3WQLZ
 Name  OnlineState  BBUReady  Status    Volt     Temp     Hours  LastCapTest
 ---------------------------------------------------------------------------
 bbu   On           Yes       OK        OK       OK       0      xx-xxx-xxxx
/c
x
 show verify
9000 series controllers support background tasks and allow you to schedule a 
regular time when they occur. 
Verify is one of the supported background tasks. Rebuild and selftest are other 
background tasks for which there are separate schedules. Migrate and 
initialize are additional background tasks that follow the same schedule as 
rebuild. For each background task, up to 7 time periods can be registered, 
known as slots 1 through 7. Each task schedule can be managed by a set of 
commands including adddelshow and set a task. Background task 
schedules have a slot id, start-day-time, duration, and status attributes. 
For details about setting up a schedule for background verify tasks, see 
“Setting Up a Verify Schedule” on page 51.
Verify activity verifies all units based on their unit type. Verifying RAID 1 
involves checking that both drives contain the exact data. On RAID 5 and 
RAID 6, the parity information is used to verify data integrity. RAID 10 and 
50 are composite types and follow their respective array types. On 9000 
series, non-redundant units such as RAID 0, JBOD, single, and spare, are also 
verified (by reading and reporting un-readable sectors). If any parity 
mismatches are found, the array will be automatically background initialized. 
(For information about the initialization process, see the user guide that came 
with your 3ware RAID controller.)
The show verify command displays the current verify background task 
schedule as illustrated below.