Справочник Пользователя для AMCC 720-0138-00

Скачать
Страница из 170
Chapter 5. Configuring Units
52
3ware Serial ATA RAID Controller User Guide for the Power Mac G5
Changing RAID Level 
You can use migrate to change the RAID level of an existing unit while the 
unit is online, without experiencing any data loss. When you change a RAID 
level, you may also add one or more drives to the unit. You can also migrate to 
change the unit's stripe size. For example, a four-drive RAID 5 with a 64KB 
stripe size can be migrated to a four-drive RAID 5 with 256KB stripe size. 
The steps below describe how to change a RAID level in 3DM2. 
                                      
                                      
To change the RAID level of a unit
1
In 3DM 2, choose 
Management > Maintenance
.
2
In the Unit Maintenance table on the Maintenance Page, select the unit for 
which you wish to change the RAID level, by checking the box next to 
the Unit ID.
3
Click the 
Migrate Unit 
button.
The Migrate dialog box appears.
4
Select any drives to be added to the unit.
5
Select the new RAID level. 
6
Optionally, select a new Stripe size.
7
Click 
OK
.
The Maintenance page updates to show the new unit and the Migration 
progress.
8
Inform the operating system of the change, as described below under 
“Informing the Operating System of Changed Configuration”
                                      
Note:
 
Once migration starts, the unit stays in the migrating state until the migration 
process is complete. The migration process cannot be aborted, and must be 
allowed to finish before a rebuild or verify to the unit is permitted.
Warning:
 
It is important that you allow migration to complete before adding to the 
unit. Making physical changes to the unit during migration may cause the migration 
process to stop, and can jeopardize the safety of your data.
Note:
 
You can only migrate a unit to a RAID level that has the same or more 
capacity as the existing one. A four-drive RAID 5 unit can migrate to a four-drive 
RAID 0, but a three-drive RAID 0 unit cannot migrate to a three-drive RAID 5, 
without adding another drive, due to the need for additional storage capacity for 
parity bits.