Листовка для Oregon Scientific IWA-80051

Скачать
Страница из 2
CMOS: TM8727-XXX, LCD-478, BATTERY 2 x AAA
Model: C8191 AWB                                                      SIZE:A4                      PANTONE: 445C
Weather Station With
Atomic Clock
Model IWA-80051
User’s Instructions
Please read these instructions carefully and store them
in  a  safe  place  for  future  reference.
  FEATURES
• Multi-language calendar: English/German/
  French/Spanish
• Manual time setting
• Daily alarm with snooze
• Indoor temperature (°C / °F selectable)
• E.L.  Backlight
• mb/hPa or inHg selectable
• 12 to 24 hour weather forecast
•  Daylight Saving Time (DST)
• Moon phase display
• Time zone display: Eastern, Central, Mountain
&  Pacific
FUNCATION KEYS
SNOOZE/LIGHT bar:
TIME  key:
ALM SET key:
UP  key:
DOWN    key:
°C/°F  key  :
mb/hPa or inHg key:
RESET  key:
ALARM ON/OF switch:
  PRODUCT DESCRIPTIONS
1.
LCD display
2.
UP key
3.
TIME key
4.
ALM SET key
5.
DOWN key
6.
°C/°F key
7.
mb/hPa or inHg key
8.
ALARM ON/OFF switch
9.
SNOOZE/ LIGHT bar
10. RESET key
11.    Battery  compartment
  DISPLAY SYMBOLS
 LCD display
1.  Weather forecast & moon phase display
2.   Clock  display
3.  Year/ month & date/alarm time display
4.   Daylight  savings  time  indicator
5. Signal strength indicator
6.  Time zone map
7.   Second  /day  of  the  week  display
8.  Atmosphere pressure display
9.  Temperature display
  NOTE:
Seconds and Day of the Week Display: Automatically
toggles  every  30  seconds  from  Day  to  Seconds.
Toggles back to Seconds after 92 seconds.
INSTALLING OR REPLACING THE BATTERIES
• Begin  by  opening  the  battery  compartment  cover
at  the  back  of  the  clock.
• Insert 2 AAA batteries (not included) into the battery
compartment and  make sure the polarity is correct
by following the (+ or -) symbols engraved inside.
• Replace the battery whenever the display becomes
dim  or  difficult  to  read.
SELECT THE TIME ZONE ( WWVB VERSION ONLY)
Make sure the time zone is already set to appropriate
location. The default time zone is Pacific zone. If your
location  is  not  of  Pacific  zone,  please  press  the  UP
key to set the desired Time zone.
RADIO CONTROLLED TIME FEATURE
After  the  first  signal  is  received,  the  clock  will
automatically  seeks  the  atomic  clock  signal  that  is
transmitted by the National Institute of Standards and
Technology in Fort Collins, Colorado. Delete all other
words  after  “Colorado”.
SIGNAL STRENGTH INDICATOR FOR RADIO
  CONTROLLED TIME SETTING
The signal indicator displays signal strength in 3 levels.
Wave segment flashing means time signals are being
received. The signal quality is indicated:
If  the  RC  clock  receives  a  successful  signal,  a
sync-time  symbol  will  appear  on  the  LCD.
Stop alarm sound and turn on
E.L.  backlight.  Pressing  and
holding  it  for  8  seconds  can
stop  the current RC reception.
In normal time mode, press it
once to toggle between month
& date and year display. Keep
it  pressed  for  2  seconds  to
enter  time  setting  mode.  In
setting mode, press it to step
the  setting  items.
In normal time mode, press it
to  display  Alarm  time.  In
Alarm  time  mode,  keep  it
pressed for 2 seconds to enter
alarm  time  setting  mode.  In
alarm time setting mode, press
it to step the setting items.
In  setting  mode,  increase  the
setting  value.  For WWVB
version, pressing UP key can
set the desired Time Zone.
In setting mode, decrease the
setting  value.  In  normal  time
mode, press it to toggle between
12 and 24hour format.
Toggle  between  °C  and  °F
format. Keep it pressed for 3
seconds  to  seek  RC  signal
instantly.
Toggle  between  mb/hPa  and
inHg  display.
In  case  of  mal-function  after
insert of battery, use a pin to
press  the  RESET  key  to
restart  the  clock.
In case of no display on LCD
while  inserting  batteries,  use
a pin to press the RESET key
to  activate  the  clock.
Switch alarm & snooze function
on  or  off.
10
11
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
8
9
7
ABOUT THE DAYLIGHT SAVINGS TIME (DST)
This clock has been pre-programmed to automatically
switch  when  daylight  savings  time  is  in  effect.  Your
clock will show “DST” on the display during this time.
NOTE:
With  the  pre-programmed  DST  feature,  if  you  live  in
an area where Daylight Savings Time is not observed,
the  time  display  on  your  clock  will  read  +/-  one  hour
during the DST time period.
  SETTING THE TIME MANUALLY
To set the time, please follow these steps:
• In  normal  time  mode,  press  the  TIME  key  for  2
seconds until the HOUR digit flashes.
• Press UP or DOWN key to change the value of the
flashing  digit.
• Press the TIME key again to step the setting items.
The  setting  sequence  will  be:  Hour  >  Minute  >
Second > Year > Month > Date > Day language.
• Press  the  UP  or  DOWN  key  to  select  the  day
language:
GB=English  FR=French  DE=German  ES=Spanish
IT=Italian
• Press TIME key to exit the setting mode.
NOTE:
In  normal  time  mode,  pressing  the  DOWN  key  will
toggle between the 12 and 24 hour formats.
  SETTING THE ALARM
• In  normal  time  mode,  press  ALM  SET  key  to  enter
alarm time mode.
• Press  the  ALM  SET  key  for  2  seconds  until  the
alarm hour digit flashes.
• Press UP or DOWN key to increase or decrease the
value  of  flashing  digit.
• Press ALM SET again to move through each setting.
The sequence will  be: Hour > Minute.
  NOTE:
12/24hour format of alarm time display are based on
the  normal  time  format.
USING THE ALARM AND SNOOZE FUNCTION
•   To activate the alarm, slide the [ALARM ON/OFF] to
the [ON] position, the bell indicator will appear on
the  display.
• To  deactivate  alarm,  slide  the  [ALARM  ON/OFF]
button to the [OFF]  position, the bell indicator will
disappear.
  NOTE:
The  snooze  will  be  on  automatically  after  activating
the alarm.
Normal Display
Hour Setting 
Day Language Setting 
Date Setting 
Second Setting 
Minute Setting 
Month Setting 
Year Setting 
Alarm Mode
Alarm Hour Setting  Alarm Minute Setting