CY8CTST120, CY8CTMG120, CY8CTMA120 
 
September 25, 2008 
 Document No. 001-49038 Rev. ** 
3.  Invalid Flash reads may occur if Vdd is pulled to -0.5V just before power on. 
 
 
PROBLEM DEFINITION 
When Vdd of the device is pulled below ground just before power on, the first read from each 8K Flash 
page may be corrupted. This issue does not affect Flash page 0 because it is the selected page upon 
reset. 
 
PARAMETERS AFFECTED  
When Vdd is pulled below ground before power on, an internal Flash reference may deviate from its 
nominal voltage. The reference deviation tends to result in the first Flash read from that page returning 
0xFF. During the first read from each page, the reference is reset. This results in all future reads returning 
the correct value. A short delay of 5 µs before the first real read provides time for the reference voltage to 
stabilize. 
 
WORKAROUND  
To prevent an invalid Flash read, a dummy read from each Flash page must occur before use of the 
pages. A delay of 5 µs must occur after the dummy read and before a real read. The dummy reads 
occurs as soon as possible and must be located in Flash page 0 before a read from any other Flash 
page. An example to read a byte of memory from each Flash page follows. Place it in boot.tpl and 
boot.asm immedi
ately after the ‘start:’ label. 
 
// dummy read from each 8K Flash page 
// page 1 
mov A, 0x20 
 
 
// MSB 
mov X, 0x00 
 
 
// LSB 
romx 
// wait at least 5 µs 
mov X, 14 
loop1: 
dec X 
jnz loop1 
 
4.  PMA Index Register fails to auto increment with CPU_Clock set to SysClk/1 (24 MHz). 
 
 
PROBLEM DEFINITION 
When the device is operating at 4.75 to 5.25V and the CPU_Clock is set to SysClk/1 (24 MHz), the USB 
PMA Index Register may fail to increment automatically when used in an OUT endpoint configuration at 
full speed. When the application program attempts to use the bReadOutEP() function, the first byte in the 
PMA buffer is always returned. 
 
PARAMETERS AFFECTED 
An  internal  flip-flop  hold  problem  associated  with  Index  Register  increment  function.  All  reads  of  the 
associated  RAM  originate  from  the  first  byte.  The  hold  problem  has  no  impact  on  other  circuits  or 
functions within the device.  
 
WORKAROUND  
To  make  certain  that  the  index  register  properly  increments,  set  the  CPU_Clock  to  SysClk/2  (12  MHz) 
during the read of the PMA buffer. An example for the clock adjustment method is listed below. 
 
PSoC  Designer
™  4.3  User  Module  Workaround:  PSoC  Designer  Release  4.3  and  subsequent 
releases includes a revised full speed USB User Module, which includes the revised firmware as shown in 
the following example. 
 
;; 
;; 24Mhz read PMA workaround 
;; 
M8C_SetBank1 
mov A, reg[OSC_CR0] 
push A