Справочник Пользователя для IBM XSERIES 220

Скачать
Страница из 178
 
 Installing options
 91
SCSI port
The server has an integrated small computer system interface (SCSI) controller with 
an internal connector (J41) on the system board. This controller supports an Ultra160 
SCSI internal channel. This channel supports up to 15 SCSI devices. In addition, this 
controller uses:
Double-transition clocking to achieve high transfer rates
Domain name validation to negotiate compatible data transfer speeds with each 
device
Cyclic-redundancy checking (CRC), instead of the usual parity checking, to 
significantly improve data reliability 
An active terminator on the system board for SCSI bus termination 
If you install a SCSI adapter in the server, you can use its SCSI connector to connect 
different types of small computer system interface (SCSI) devices.  
Note:
If you install a PCI redundant array of independent disks (RAID) adapter, you 
can move the SCSI cable from the system-board SCSI connector to an internal 
channel connector on the RAID adapter if you want to control the internal 
drives from the adapter.
SCSI cabling requirements
A SCSI cable comes with the server so that you can connect internal SCSI devices to 
the SCSI controller on the system board. A 2-drop SCSI cable comes with the models 
that have the hot-swap drive cage option. A 5-drop SCSI cable comes with the models 
that have the standard non-hot-swap drive cage. If you plan to use the SCSI cable to 
connect internal SCSI devices to another SCSI or ServeRAID controller (for example, 
an optional PCI adapter), you must purchase and install an optional SCSI cable to 
connect other SCSI devices (for example, a tape drive) to the SCSI connector on the 
system board. If you plan to attach external SCSI devices, you must install an optional 
SCSI adapter and order additional SCSI cables. 
For information about the maximum length of SCSI cable between the terminated 
ends of the cable, refer to the ANSI SCSI standards. Adhering to these standards will 
help ensure that the server operates properly.
Setting SCSI IDs 
Each SCSI device that is connected to a SCSI controller or adapter must have a unique 
SCSI ID. This ID enables the SCSI controller or adapter to identify the device and 
ensure that different devices on the same SCSI channel do not attempt to transfer data 
simultaneously. SCSI devices that are connected to different SCSI channels can have 
duplicate SCSI IDs. 
To install external SCSI devices, you must first install an optional SCSI PCI adapter. 
Refer to the information that is provided with the device for instructions to set its SCSI 
ID.
4
Not connected
9
PIN
14
Vertical synchronization 
(Vsync)
5
Digital return
10
Digital return
15
DDC SCL
Pin
Signal
Pin
Signal
Pin
Signal
Table 14. Video-port connector pin-number assignments.