Design and Environmental Specifications 
Intel® Server Boards S5000PSL and S5000XSL TPS 
 
LP Riser TYPE 1 
LP Riser Type 0 
GPI: 
ESB2 GPI 28 
GPI: 
ESB2 GPI 27 
SLOT 6 SETUP
 1
 
 
PCI-E Pin:  B48 [RSVD] 
PCI-E Pin:  B49 [GND] 
2U Riser, 2 x4 PCI Express* Slots
2
 0 
1U Riser, 1 x8 PCI Express* Slot
3
 1 
Notes: 
1  The server board contains a weak pull-up resistor on the two Riser Type nets. 
2  The 2U riser card needs to pull-down the PCI Express* pin B48 with a 0 ohm resistor 
and leave as a No-Connect (NC) PCI Express* pin B49. 
3  The 1U riser card needs to follow the standard PCI Express* Adapter pin-out by leaving 
pin B48 as a No-Connect (NC) and pin B49 as ground. 
 
The following table provides the supported bus throughput for the given riser card used and the 
number of add-in cards installed.  
PCI Express* Slot 6 Riser 
Support  
1 add-in card 
2 add-in cards 
1U Riser Card 
X8 
NA 
2U Riser Card 
X4 
X4 
 
Note: There are no population rules for installing a single add-in card in the 2U riser card; a 
single add in card can be installed in either PCI Express* slot. 
3.2.2 
Serial ATA Support 
The ESB2-E has an integrated Serial ATA (SATA) controller that supports independent DMA 
operation on six ports and supports data transfer rates of up to 3.0 Gb/s. The six SATA ports on 
the server board are numbered SATA-0 thru SATA-5. The SATA ports can be enabled/disabled 
and/or configured by accessing the BIOS Setup utility during POST.  
3.2.2.1 Intel
®
 Embedded Server RAID Technology II Support  
The onboard storage capability of this server board includes support for Intel
®
 Embedded 
Server RAID Technology which provides three standard software RAID levels: data stripping 
(RAID Level 0), data mirroring (RAID Level 1), and data stripping with mirroring (RAID Level 
10).   For higher performance, data stripping can be used to alleviate disk bottlenecks by taking 
advantage of the dual independent DMA engines that each SATA port offers. Data mirroring is 
used for data security. Should a disk fail, a mirrored copy of the failed disk is brought on-line. 
There is no loss of either PCI resources (request/grant pair) or add-in card slots. 
With the addition of an optional Intel RAID Activation Key, Intel
®
 Embedded Server RAID 
Technology is also capable of providing fault tolerant data stripping (software RAID Level 5), 
such that if a SATA hard drive should fail, the lost data can be restored on a replacement drive 
from the other drives that make up the RAID 5 pack. 
See Figure 2 Major Board Components for the location of Intel RAID Activation Key connector 
location.  
Note: Availability of the Intel RAID Activation Key to support software RAID 5 will be deferred 
until after product launch of this server board. 
  
Revision 
1.2 
Intel order number: D41763-003 
44