Design and Environmental Specifications
Intel® Server Boards S5000PSL and S5000XSL TPS
Connector
Quantity
Reference Designators
Connector Type
Pin
Count
LCP/AUX IPMB
1
J2J1
Header
4
IPMB 1
J4J1
Header
3
HDD Activity
1
J2J3
Header
2
Configuration
jumpers
jumpers
4
J1D2 (Password Clear), J1D1 (CMOS Clear), J1C3
(BIOS Bank Select), J1E3 (BMC Force Update)
(BIOS Bank Select), J1E3 (BMC Force Update)
Jumper 3
5.2 Power
Connectors
The main power supply connection uses an SSI-compliant 2x12 pin connector (J9B5). In
addition, there are three additional power related connectors:
addition, there are three additional power related connectors:
One SSI-compliant 2x4 pin power connector (J3J2) provides 12V power to the CPU
Voltage Regulators
Voltage Regulators
One SSI-compliant 1x5 pin connector (J9D1) provides I
2
C monitoring of the power
supply
One SSI-compliant 2x2 pin connector (J5A2) provides additional 12V power to the
server board
server board
The following tables define the connector pin-outs.
Table 11. Power Connector Pin-out (J9B5)
Pin
Signal
Color
Pin
Signal
Color
1
+3.3 Vdc
Orange
13
+3.3 Vdc
Orange
2
+3.3 Vdc
Orange
14
-12 Vdc
Blue
3 GND
Black 15 GND
Black
4 +5
Vdc Red 16 PS_ON# Green
5 GND
Black 17 GND
Black
6 +5
Vdc Red 18 GND
Black
7 GND
Black 19 GND
Black
8 PWR_OK
Gray 20 RSVD_(-5
V)
White
9
5 VSB
Purple
21
+5 Vdc
Red
10 +12
Vdc Yellow 22 +5
Vdc
Red
11 +12
Vdc Yellow 23 +5
Vdc
Red
12 +3.3
Vdc Orange 24 GND
Black
Revision
1.2
Intel order number: D41763-003
54