8.3.9 
Residual Voltage Immunity in Standby Mode 
The power supply should be immune to any residual voltage placed on its outputs (typically, a 
leakage voltage through the system from standby output) up to 500 mV. There shall be no 
additional heat generated, nor stressing of any internal components with this voltage applied to 
any individual output, and all outputs simultaneously. It also should not trip the power supply 
protection circuits during turn on.  
Residual voltage at the power supply outputs for a no load condition shall not exceed 100 mV 
when AC voltage is applied and the PSON# signal is de-asserted.