Power Management 
 
 
 
 
User’s Manual 
 22 
    Document Number: 320264 
 
 
Agilent 34401A (6½ digit 
display) 
Fluke 79 (3 digit display) 
Specification 
(±0.0030  % of reading) 
+ (±0.0030  % of range) 
±0.09% ±2 digits 
Min Voltage displayed 
Calculated power 
1.49193  mV 
0.22258  mW 
1.47  mV 
0.216 mW 
Max voltage displayed 
Calculated power 
1.49206  mV 
0.22624  mW 
1.51  mV 
0.228  mW 
Error in power 
±0.009 % 
±0.3  % 
NOTE:  The precision achieved by using a high precision digital multi-meter versus a normal 
digital multi-meter is ~33 times more accurate. 
Table 7
 summarizes all the power measurement sense resistors located on the Crown 
Beach board. All sense resistors are 0.01 Ω unless otherwise noted. 
Table 7. Crown Beach Voltage Rails 
Sch Page 
Comp
onent 
Vo
lt
age
 
Supply 
Rail 
Ref
 Des 
Res
istor 
Supply  Po
w
e
Topo
lo
gy 
11 SCH  1.8 
+V1.8 
+V1.8_SM_SCH  R5T3 
0.01, 
1% 
DDR2_VR 
11 SCH  1.05 
V +V1.05S_SCH 
+V1.05S_SCH_VCORE 
R6T7 
0.01, 
1% 
VCORE 
11 SCH  1.5 
V  +V1.5S_SCH +V1.5S_DLVDS_SCH 
R6T9 
0.01, 
1% 
LVDS 
11 SCH  3.3 
+V3.3 
+V3.3_SCH_SUS R6T13 
0.01, 
1% 
SUS 
11 SCH  3.3 
+V3.3S 
+V3.3S_SCH  R5T5 
0.01, 
1% 
3.3 V 
11 SCH  1.05 
V +V1.05S_VTT +V1.05S_VTT_SCH 
R5U35 
0.01, 
1% VTT 
SCH 
11 
SCH 
1.5 V 
+V1.5S  
+V1.5S_SCH 
R5T6 
0.01, 
1% 1.5CORE 
11 SCH  1.5 
V  +V1.5S_SCH +V1.5S_SDVO_SCH 
R6T10 
0.01, 
1% 
SDVO 
11 SCH  1.05 
V +V1.05S_VTT +V1.05S_VTT_CPU R3U1 
0.01, 
1% VTT 
CPU