Reference Board Summary 
 
 
 
 
User’s Manual 
 30 
    Document Number: 320264 
Table 9. Configuration Jumper/Switches Settings 
Description Default 
Setting
1
 Optional 
Setting 
Reference 
Designator 
1a 
Remote H8 
Programming 
Open 
1-2 (Short) – to 
program H8 
3
 
J8E1 
J8E4 
1b 
Remote H8 
Programming 
(BB_PROG) 
1-2 – normal operation  
1-x – link the Host Unit 
to On Board H8  
J8D4 
Virtual Battery 
Switch 
1-2 (UP) – normal 
operation 
Virtual Battery switch 
is pulled high 
(disabled). The system 
acts as if it is running 
on AC power 
2-3 (DOWN) – Virtual 
Battery switch is pulled 
low. This enables the 
virtual battery and the 
system acts as if it is 
running from a battery 
source 
SW8A1 
2
 
Virtual Battery 
Jumper 
1-x (OUT) – normal 
operation 
Virtual battery status 
is controlled by SW9A2 
1-2 (IN) – Override 
switch SW9A2 condition. 
System will always act 
as if it is running from a 
battery source 
J8A1 
4 Lid 
Jumper 
1-x (OUT) – normal 
operation 
No effect on circuit. 
1-2 (IN) - Override 
switch condition, pulled 
low 
J9A1 
5 Lid 
Switch 
1-2 (UP) – normal 
operation 
LID switch is pulled 
high 
2-3 (DOWN) – LID 
switch is pulled low 
SW9A1 
2
 
6 Clear 
RTC 
1-x (OUT) – normal 
operation 
1-2 (IN) to clear CMOS 
J4H1 
Force Shutdown 
No Stuff 
Reserved 
J7G1 
8a 
BSEL0 Setting 
No Stuff 
Reserved 
J8G2 
8b BSEL1 
Setting 
1-2 – Processor BSEL 
Select 
OUT – 400 MHz 
OUT – 533 MHz 
J8G3 
8c BSEL2 
Setting 
1-2 – Processor BSEL 
Select 
2-3 – 400 MHz 
OUT – 533 MHz 
J9G3 
9a 
Manual VIDs: 
VID 6 (1-2) 
VID 5 (3-4) 
VID 4 (5-6) 
VID 3 (7-8) 
VID 2 (9-10) 
VID 1 (11-12) 
VID 0 (13-14) 
IN – normal operation 
(1-2) 
(3-4) 
(5-6) 
(7-8) 
(9-10) 
(11-12) 
(13-14) 
OUT – Refer to  
Section 4.5
 and 
Appendix B
 
J1B1