 47 
Function Reference 
Designator 
VID 0 
CR1B1 
VID 1 
CR1B2 
VID 2 
CR1B3 
VID 3 
CR1B4 
VID 4 
CR1B5 
VID 5 
CR1B6 
VID 6 
CR1B7 
M0/M1 CR4H1 
System Power Good 
CR5J1 
Reserved CR8G1 
4.6 
Other Headers, Slots and Sockets 
4.6.1 
H8 Programming Headers 
The microcontroller firmware for system management/keyboard/mouse control can be 
upgraded in two ways.  The user can either use a special DOS* utility known as 
KSCFlash (in-circuit) or use an external computer connected (remote) to the system 
via the serial port on the development board. KSCFlash is available on request from 
your Intel representative. 
If the user chooses to use an external computer connected to the system via the serial 
port, there are four jumpers that must be set correctly first.  Please refer to 
Table 15
 
for a summary of these jumpers and refer to 
Figure 7
 for the location of each jumper. 
Required Hardware: one Null Modem Cable and a Host Unit with a serial COM port 
(System used to flash the development board) 
Here is the sequence of events necessary to program the H8 via the serial port. 
1.  Extract all files (keep them in the same folder) to a single directory of your 
choice on the host machine or on a floppy disk. 
2.  Connect a NULL modem cable to the serial ports of each platform (host and 
unit to be flashed). 
3.  With the development board powered off, move the following jumpers to the 
programming stuffing option. 
a.  J9G2 (remove) (default: 1-2), Sets SMC_INIT_CLK high. 
b.  J8B1 (2-3) (default: 1-2), link the Host Unit to on-board H8. 
c.  J8B2 (2-3) (default: 1-2), link the Host Unit to on-board H8.