VTrak M310p, M210p Product Manual
156
Dedicated means this spare drive can only be used with the specified disk 
array(s). Global means this spare drive can be used by any disk array.
5.
If you chose Dedicated, highlight Dedicated to Arrays and press the 
backspace key to erase the current value, then type the new value.
Specify the number(s) of the disk array(s) you want to assign your spare. 
The current disk arrays are listed in parentheses.
6.
Press Ctrl-A to save the spare drive.
Spare Drive Settings
 This screen displays information about a spare drive. It enables you to change 
the settings for this spare drive:
Revertible – Yes means the drive automatically returns to its spare drive 
assignment after the failed physical drive is replaced.
Type – Global or Dedicated (to a specific disk array)
To change these settings:
1.
Highlight the setting you want to change.
2.
Press the spacebar to toggle between the choices.
3.
For dedicated spares, type the array number it is assigned to.
4.
Press Ctrl-A to save your settings.
To run spare check, highlight Start Spare Check and press Enter. The results 
appear next to Spare Check Status.
Delete Spare Drive
 
1.
Highlight the spare drive you want to delete and press the spacebar to mark 
it.
The mark is an asterisk (*) to the left of the listing.
2.
Highlight Delete Marked Spare Drives and press Enter.
3.
Press Y to confirm the deletion.
LUN Mapping
This function enables you to assign a Target and LUN to each logical drive, so 
the SCSI initiator can recognize it.
Caution
If the spare drive you delete is the only spare, the controller will not 
rebuild a critical array until you provide a new spare drive.