Справочник Пользователя для Promise Technology M310p

Скачать
Страница из 262
Chapter 7: Technology Background
199
Predictive Data Migration (PDM)
Predictive Data Migration (PDM) is the migration of data from the suspect disk 
drive to a spare disk drive, similar to Rebuilding a Logical Drive. But unlike 
Rebuilding, PDM constantly monitors your disk drives and automatically copies 
your data to a spare disk drive before the disk drive fails and your Logical Drive 
goes Critical.
After the data is copied from the suspect disk drive, the controller marks it with a 
Stale configuration and a PFA error.
You can clear the Stale configuration and PFA error and put the disk drive back 
into service. See “Clear Physical Drive Conditions” on page 89 for WebPAM 
PROe or see “Clear Stale and PFA Conditions” on page 139 for the CLU. In most 
cases, however, you will remove the disk drive for repair or replacement.
PDM Triggers
The following actions trigger PDM:
A disk drive with unhealthy status (see below) 
Media Patrol finds a disk critical error* 
You initiate PDM manually 
*PDM also counts the number of media errors reported by Media Patrol. 
A disk drive becomes unhealthy when: 
A SMART error is reported 
The bad sector remapping table fills to the specified level 
Because data would be lost if written to a bad sector, when a bad sector is 
detected, the disk drive creates a map around it. These maps are saved in the 
bad sector remapping table, which has a capacity of 512 reassigned blocks and 
1024 error blocks.
When the table fills to a specified percentage of its capacity, PDM triggers a 
migration of data from the suspect drive (the disk drive with the bad sectors) to a 
spare disk drive. 
During data migration, you will have access to the Logical Drive but it will respond 
more slowly to read/write tasks because of the additional operation. The time 
required for data migration depends on the size of the disk drive.