DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-59
ANL-16-L (16-Port Neon Analog Line) 
10
Loop Around Test (#161)
Each Analog port consists of:
an NPE for port connectivity and gain, and conferencing functionality
a code that converts the digital signals of the TDM Bus to analog signals
a battery feed chip that provides power to the telephone set for signaling, 
dial pulsing, transmission, and balance
This test is designed to check the on-board transmission capabilities of the NPE, 
the codec, and the battery feed chip of the analog port. A Tone Detector and a 
Tone Generator talk and listen on the same pair of time slots as the Analog Port. 
The Analog Port is then instructed to go into loop around mode (see the following 
below). The test passes if the signal measured by the Tone Detector is within 
acceptable limits.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
dispatch to check to ensure that there is a valid board inserted.
Table 10-24.
TEST #48 Station Present Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page