Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-164
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
k. This error occurs when an SPID initialization request is made from an 
endpoint and the switch determines that the SPID value is invalid or is a 
duplicate of another SPID that is already initialized at Layer 3 on the port. 
Check the administration of the endpoints.
l. This error occurs when the circuit pack detects an overflow of its receive 
buffers. Run the Long Test Sequence, and pay particular attention to the 
results of the Receive First In First Out (FIFO) Overflow Error Counter Test 
(#625).
m. This error occurs when the BRI Port Local LAN Loop Around Test (#618) 
fails. Run the Long Test Sequence, and pay particular attention to the 
results of Test #618.
n. This error most likely occurs when the Terminal Endpoint Identifier (TEI) 
administered for the ASAI or AT&T endpoint does not match the TEI 
administered in the ASAI or AT&T adjunct. Check the switch 
administration of the TEI against that of the adjunct, and make sure that 
both are using the same TEI.
o. Indicates that sets on the port do not support Layer 3 initialization. Consult 
the Service Set documentation.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test
, for example, you may also clear errors generated from other tests 
in the testing sequence.
Order of Investigation
Short Test 
Sequence
Long 
Test 
Sequence
D/ND
1
NPE Crosstalk Test (#617)
X
D
BRI Port Local LAN Loop Around Test 
(#618)
X
D
BRI Port Local TDM Loop Around Test 
(#619)
X
D
Electronic Power Feed Restoral Test 
(#620)
X
X
ND
Level 1 Status Inquiry Test (#621)
X
X
ND
Electronic Power Feed Inquiry Test (#622)
X
X
ND
CRC Error Counter Test (#623)
X
ND