DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-181
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
Electronic Power Feed Inquiry (#622)
This test queries the BRI-LINE circuit pack for the status of the Electronic Power 
Feed (EPF) supplied to a BRI endpoint or an ASAI or AT&T adjunct. If the EPF is 
on and no overcurrent condition exists, this test passes. All other states are not 
normal and indicate a problem with the endpoint or adjunct, the wiring to the 
endpoint or adjunct, or the BRI-LINE circuit pack. This test is not run on the 
TN2208 circuit pack or the TN2198 and will always return a pass for a TN2198. 
The TN2208 has no power feeds.
Table 10-59.
TEST #622 Electronic Power Feed Inquiry 
Error 
Code
Test 
Result
Description/ Recommendation
1005
ABORT
This test is not valid for this port type. Ports on the 
TN2208 cannot run this test because this board does 
not have an electronic power feed.
2000
ABORT
Response to the test was not received from the circuit 
pack within the allowable time period.
1. If the test aborts repeatedly a maximum of five times, 
reset the circuit pack via the 
busyout board PCSS
 
and 
reset board PCSS
 commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal System Error.
2100
ABORT
Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page