DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Routine Maintenance Procedures 
Page 5-23
Software Upgrade 
5
press 
Enter. 
Where P is the port network number (1 for PPN, and 2-4 for 
EPN), C is the carrier designation (A, B, C, or D), and SS is the number of 
the slot in which the circuit pack resides (01 to 21). 
NOTE:
If multiple TN750/B circuit packs are present, you 
must
 specify the 
slot location for the save announcements command. If there is only 
one announcement circuit pack, the system defaults to the proper 
location.
NOTE:
The TN750C Announcement circuit pack has on-board non-volatile 
storage and does not need to be saved to the translation card.
Shut Down DEFINITY LAN Gateway System
If a DEFINITY LAN Gateway system resides in the control cabinet to be 
upgraded, prepare to shut down the DEFINITY LAN Gateway assembly and 
allow the disk to completely spin down.
!
CAUTION:
Save the system parameters if you plan to reuse the current system.
!
CAUTION:
Neglecting to shut down a DEFINITY LAN Gateway assembly before 
powering down the system cabinet where it resides can damage the LAN 
Gateway disk.
1. Log onto the DEFINITY LAN Gateway. 
See the DEFINITY Communications 
System Generic 3 Installation, Administration and Maintenance of 
CallVisor ASAI over the DEFINITY LAN Gateway
, 555-230-223, for the 
procedure to log on.
2. When the main menu appears, select 
Maintenance
.
3. Select 
Reset System
 from the 
Maintenance
 menu.
4. Select 
Shutdown
 from the 
Reset System
 menu.
5. Unseat the LAN Gateway assembly from its backplane connectors. 
Shut Down DEFINITY AUDIX System
1. If a DEFINITY AUDIX System resides in the control cabinet to be 
upgraded, shut down the AUDIX assembly and allow the disk to 
completely spin down.