DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-262
CARR-POW (Carrier Port Power Unit) for AC-Powered Systems 
10
CARR-POW (Carrier Port Power Unit)
for AC-Powered Systems
DEFINITY Generic 1 offers two basic cabinet type configurations: (1) the 
multicarrier cabinet system and (2) the single-carrier cabinet system. Both 
cabinet system configurations may be powered by either an external AC or DC 
power source.
NOTE:
For environment maintenance, the aspects of a PPN configuration for a 
High or Critical Reliability system or of an EPN cabinet configuration are 
irrelevant.
The environment maintenance strategy to be used depends on both the cabinet 
configuration and the type of powering. Therefore, refer to the following list to find 
the appropriate MO section(s).
For a single-carrier cabinet system, refer to the "DC-POWER" Maintenance 
documentation for environment maintenance strategy.
For a multicarrier cabinet system using an external AC power source, refer 
to one or more of the following Maintenance documentation sections: 
"AC-POWER", "CUST-ALM (Customer-Provided Alarming Device)", or 
"POWER (Battery & Battery Charger) for AC-Powered Systems".
For a multicarrier cabinet system using an external DC power source, refer 
to one or more of the following Maintenance documentation sections: 
"AC-POWER (AC Power) for DC-Powered Systems", "CUST-ALM 
(Customer-Provided Alarming Device)", or "POWER (Battery & Battery 
Charger) for DC-Powered Systems".
Every carrier in the system must be supplied with +5 volt, -48 volt, and -5 volt DC 
power for the various circuit packs to operate properly. This power is supplied to 
the carriers as follows: AC from a wall outlet comes into the PDU, which 
distributes the power via a set of fuses (F1 to F7) to the power units. Each carrier 
in the system is equipped with two power units: the 631 DA AC power unit and 
the 631 DB AC power unit, which together supply the required voltages to the 
carrier. Figure 10-12 illustrates the position of the power unit and the power 
distribution unit (PDU) and shows which power unit each fuse controls (Figure 
10-12 also shows other Environment maintenance-related items that can be 
1.
Recycle the carrier indicated by the PORT field in the Alarm Log.
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
1
Full Name of MO
CARR-POW
MAJOR
recycle carrier PC
Carrier Port Power Unit