Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-273
CARR-POW (Carrier Port Power Unit) for AC-Powered Systems
10
System Technician-Demanded Tests:
Descriptions and Error Codes
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
inspecting errors in the system. By clearing error codes associated with the
Battery & Battery Charger Query Test
, for example, you may also clear errors
generated from other tests in the testing sequence.
Notes:
a. Refer to POWER (Battery & Battery Charger) Maintenance documentation
for a description of this test.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
Battery & Battery Charger Query Test
(#5) (a)
(#5) (a)
X
X
ND
AC Power Query Test (#78) (b)
X
X
ND
Power Unit Query Test (carrier E)
(#127)
(#127)
X
X
ND
Power Unit Query Test (carrier D)
(#127)
(#127)
X
X
ND
Power Unit Query Test (carrier A)
(#127)
(#127)
X
X
ND
Power Unit Query Test (carrier B)
(#127)
(#127)
X
X
ND
Power Unit Query Test (carrier C)
(#127)
(#127)
X
X
ND
Emergency Transfer Query Test
(#124) (c)
(#124) (c)
X
X
ND
Cabinet Temperature Query Test
(#122) (d)
(#122) (d)
X
X
ND
External Alarm Lead Query Test
(#120) (e)
(#120) (e)
X
X
ND
Analog Ring Generator Initialization
Test (#117) (f)
Test (#117) (f)
X
X
ND
Analog Ring Generator Query Test
(#118) (f)
(#118) (f)
X