DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-292
CARR-POW (Carrier Port Power Unit) for DC-Powered Systems 
10
f. Refer to RING-GEN (Analog Ring Generator) Maintenance documentation 
for a description of this test.
NOTE:
This test only shows up in the test sequence if there is a TN768 
Tone-Clock circuit pack in the port network being tested.
Power Unit Recycle Test (#126)
This test is destructive.
This test is destructive because it requires all circuit packs in the recycled carrier 
to be removed and inserted. These actions cause all calls originating or 
terminating on circuit packs in this carrier to be dropped. The pair of port carrier 
power units in the specified carrier is recycled. Both port carrier power units in 
the carrier are turned off for two seconds and then back on. After the port carrier 
power units have been turned back on, the test queries the Maintenance/Tape 
Processor in Standard system PPN, the Duplication Interface circuit pack in a 
PPN for a High or Critical Reliability system, or the EPN Maintenance circuit pack 
in an EPN multicarrier cabinet system for the status of the pair of port carrier 
power units in the specified carrier. If both port carrier power units are on and 
functioning, then the test passes. If both port carrier power units are not on and 
functioning, the test fails, and BOTH port carrier power units are turned off.
Table 10-84.
TEST #126 Power Unit Recycle Test 
Error Code
Test 
Result
Description/ Recommendation
1000
ABORT
System resources required to run this test are not 
available.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the 
problem.
1129
ABORT
Only occurs when recycling carrier 2B. Indicates 
that the Active Tone-Clock for the EPN is in carrier 
2B.
1. Issue the 
set tone-clock 2A
 command.
2. Rerun the test.
Continued on next page