Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-308
CO-DS1 (DS1 CO Trunk) 
10
Hardware Error Log Entries and Test to Clear 
Values
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test 
description and follow the recommended procedures.
2.
This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator field set 
to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of service, 
then the alarm will be upgraded to a MAJOR alarm.
DS1CO Trunk Error Log Entries
Error Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test trunk 
<grp>/<mbr>
1 (a)
57408
1 (a)
57487
15 (b)
Any
Port Audit and 
Update Test (#36)
18 (c)
0
busyout trunk 
<grp>/<mbr>
WARNING
OFF
release trunk 
<grp>/<mbr>
130 (d)
None
WARNING
ON
test trunk 
<grp>/<mbr>
257 (e)
57392
DS1 CO Dial Tone 
Seizure Test (#314)
MIN/MAJ
2
OFF
513 (f)
57393
DS1 CO Dial Tone 
Seizure Test (#314)
MIN/MAJ
2
OFF
769 (g)
57484
1025
DS1CO Dial Tone 
Seizure Test (#314)
WARNING
OFF
test trunk 
<grp>/<mbr>
1281
Conference Circuit 
Test (#7)
MAJ/MIN/ 
WRN
3
ON
test trunk 
<grp>/<mbr> r 4
1537
NPE Crosstalk Test 
(#6)
MAJ/MIN/ 
WRN
3
ON
test trunk 
<grp>/<mbr> r 3
1793 (h)
ON
test board PCSS l
2562(i))
16665
2817(j)
52992
3840 (k)
Port Audit and 
Update Test (#36)