Routine Maintenance Procedures 
Page 5-31
Software Upgrade 
5
2. When the main menu appears, select 
Maintenance
.
3. Select 
Reset System
 from the 
Maintenance
 menu.
4. Select 
Shutdown
 from the 
Reset System
 menu.
5. Unseat the LAN Gateway assembly from its backplane connectors.
Shut Down DEFINITY AUDIX System
1. If a DEFINITY AUDIX System resides in the control cabinet to be 
upgraded, shut down the AUDIX assembly and allow the disk to 
completely spin down.
!
WARNING:
Neglecting to shut down AUDIX before powering down the system 
cabinet where it resides can damage the AUDIX disk.
2. Manually Power Down AUDIX System
A yellow caution sticker on the system’s power unit notifies technicians to 
shut down the DEFINITY AUDIX System prior to powering down the 
system.
a. Using a pointed object, such as a paper clip or pen (do not use a 
pencil), press the Boot/shutdown button. The button is located at 
the top right portion of the front panel.
b. Hold the boot/Shutdown button in until the LCD display flashes the 
message 
MSHUT.
c. Release the Boot/Shutdown button.
NOTE:
The DEFINITY AUDIX System takes about five minutes to shut 
down. The “heartbeat” indication on the display continues to 
flash.
3. Unseat the AUDIX assembly from its backplane connectors in the carrier. 
Power Down Basic Control Cabinet
!
CAUTION:
Do not power down the entire system. This defeats the purpose of high or 
critical reliability configurations.
!
CAUTION:
Powering down the control cabinet causes important system data, such as 
BCMS data, records of queued ACD calls, Automatic Wakeup request, and 
Do Not Disturb requests to be lost. Refer to DEFINITY Enterprise