Routine Maintenance Procedures 
Page 5-35
Software Upgrade 
5
NOTE:
The TN750C Announcement circuit pack has on-board non-volatile 
storage and does not need to be saved to the translation card.
Enable TTI
If TTI was enabled prior to the software upgrade:
1. Enter 
change system-parameters features
 and press 
Enter
2. Use page 2 of the form to change the TTI field back to 
y
 (if necessary).
Enable Scheduled Maintenance
Enter 
change system-parameters maintenance
, and press 
Enter
. Use this form 
to enable scheduled daily maintenance.
Enable Customer Options
1. Enter 
change system-parameters customer-options
 and press 
Enter
.
2. Use these forms to verify the customer options are properly set.
NOTE:
In the 
Basic Call Setup 
field, if 
ISDN-PRI? 
was set to 
y 
before the 
upgrade, be sure to set the field back to 
y
.
Resolve Alarms
Examine the alarm log. Resolve any alarms that may exist using 
DEFINITY 
Enterprise Communications Server Release 5.4 Maintenance for R5vs/si
Verify Alarm Origination to INADS
Be sure the system is part of the existing INADS database by calling the INADS 
Database Administrator at the Technical Service Center (TSC). Verify that INADS 
can dial into the system and that the system can dial out to INADS. 
As part of the system registration process, the INADS Database Administrator 
enables Alarm Origination.
Return Equipment
Return the replaced equipment (including the old Translation Card) to Lucent 
Technologies according to the requirements outlined in the following documents:
BCS/Material Logistics, MSL/Attended Stocking Locations
Methods and Procedures for Basic Material Returns