DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-446
DID-TRK (DID Trunk) 
10
Hardware Error Log Entries and Test to Clear 
Values
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the 
set 
options
 command. If the Minor alarm is not downgraded by the 
set-options
 values, the Minor alarm is 
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
DID Trunk Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
None
WRN
OFF
1 (b)
57476
None
WRN
OFF
1 (c)
57477
None
WRN
OFF
1 (d)
57483
None
WRN
OFF
15 (e)
Any
Port Audit Update 
(#36)
18
0
busyout trunk 
<grp/mbr>
WRN
OFF
release trunk <grp/mbr>
130 (f)
None
WRN
ON
test trunk <grp>/<mbr>
257 (g)
57472
None
WRN
OFF
257 (h)
57473
None
WRN
OFF
257 (i)
57474
None
WRN
OFF
257 (j)
57475
None
WRN
OFF
513 (k)
57392
None
MAJ/MIN/
 WRN
2
OFF
510 (l)
57393
None
769
Any
Port Diagnostic 
(#35)
MAJ/MIN/
 WRN
ON
test port PCSSpp r 3
1025
Loop Around and 
Conference (#33)
MAJ/MIN/
 WRN
ON
test port PCSSpp r 3
1281
NPE Crosstalk (#6)
MAJ/MIN/
 WRN
ON
test port PCSSpp r 3
1537
Any
Port Diagnostic 
(#35)
MAJ/MIN/
 WRN
OFF
test port PCSSpp r 3
1793 (m)
57489
None
None