DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-525
DIOD-TRK (DIOD Trunk) [G1.2SE] 
10
Port Audit Update Test (#36)
This test sends updates of the CO port translation for all ports on the circuit pack 
which have been translated. The update is non-disruptive and guards against 
possible corruption of translation data contained on the circuit pack. No 
response message is expected from the circuit pack once it receives translation 
updates. The port translation data includes: ground or loop start trunk, tone or 
rotary dialing trunk, rotary dialing inter-digit timing, network balance R/RC, and 
disconnect timing.
7
FAIL
1. Check for errors on TONE-BD or TONE-PT. If there are 
errors, take the appropriate actions.
2. If the Reflective Loop Around Test fails for all ports on a 
circuit pack, a -5 volt power problem is indicated. If a 
TN736 or TN752 power unit circuit pack is present, 
check the circuit pack for a red LED. If the red LED is 
on, then replace the appropriate power unit circuit 
pack. If neither the TN736 nor the TN752 power unit 
circuit pack is present, then the OLS631DB AC power 
unit may be defective. The system may contain a 
TN736 or TN752 power unit circuit pack OR an 
OLS631DB AC power unit, BUT NOT BOTH TYPES OF 
POWER UNITS.
NOTE:
To investigate problems with an OLD631DB AC 
power source, refer to CARR-POW Maintenance 
documentation.
3. Rerun the test.
4. If the test fails again, replace the circuit pack.
PASS
CO Trunk Loop Around and Conference Test is successful. 
User-reported troubles on this port should be investigated 
by using other port tests and by examining trunk or external 
wiring.
Table 10-142.
TEST #33 Loop Around and Conference 
Circuit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page