DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-537
DS1-BD (DS1 Interface Circuit Pack) 
10
the circuit pack has not been taken out-of-service, but it has generated 
50% of the messages necessary to be considered hyperactive. This may 
be completely normal during heavy traffic periods. However, if this error 
type is logged when the circuit pack is being lightly used, it may indicate a 
problem with the circuit pack or the equipment attached to it.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in Table 10-145. By 
clearing error codes associated with the 
NPE Connection Audit Test,
 for 
example, you may also clear errors generated from other tests in the testing 
sequence
Table 10-145.
System Technician-Demanded Tests: DS1-BD
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Reset 
Board 
Sequence
test 
ds1-loop 
Command
D/ND
1
NPE Connection Audit Test (#50)
X
ND
Control Channel Loop Test (#52)
X
ND
Loss of Signal Alarm Inquiry Test 
(#138)
X
X
ND
Blue Alarm Inquiry Test (#139)
X
X
ND
Red Alarm Inquiry Test (#140)
X
X
ND
Yellow Alarm Inquiry Test (#141)
X
X
ND
Major Alarm Inquiry Test (#142)
X
X
ND
Minor Alarm Inquiry Test (#143)
X
X
ND
Slip Alarm Inquiry Test (#144)
X
X
ND
Misframe Alarm Inquiry Test (#145)
X
X
ND
Translation Update Test (#146)
X
X
ND
ICSU Status LEDs Test (#1227)
X
X
ND
SAKI Sanity Test (#53)
 
 
X
D
Internal Looparound Test (#135)
X
D
DS1/CSU Loopback Tests
X
D
DS1 Board Loopback Test (#1209)
X
D
Continued on next page