Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-542
DS1-BD (DS1 Interface Circuit Pack) 
10
Internal Looparound Test (#135)
This test is destructive.
The Internal Looparound Test is run by looping the transmitted DS1 bit stream 
back into the DS1’s board receiver. The loop occurs just before the DS1 facility 
1015
ABORT
Port is not out-of-service. 
1. Busyout the circuit pack.
2. Execute the command again.
2100
ABORT
System resources required for this test are not available. 
1. Retry the command at 1-minute intervals a maximum of 5 times.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart. 
1. Execute the command again.
2. If the problem persists, replace the circuit pack.
PASS
The circuit pack initializes correctly. 
1. Run the Short Test Sequence.
0
NO BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an 
incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add 
ds1 PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is 
shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal ID and the port.
Table 10-148.
TEST #53 SAKI Sanity Test  — 
Continued
Error 
Code
Test Result
Description/ Recommendation
Continued on next page