Maintenance Object Repair Procedures 
Page 10-551
DS1-BD (DS1 Interface Circuit Pack) 
10
Blue Alarm Inquiry Test (#139)
The Blue Alarm is a signal sent by the remote DS1 endpoint when it is 
out-of-service. The Blue Alarm Inquiry Test checks the blue alarm status of the 
remote DS1 endpoint.
When the DS1 Interface circuit pack detects a Blue Alarm signal from the remote 
DS1 endpoint, the circuit pack will transmit a Yellow alarm to the remote DS1 
endpoint and send a BLUE ALARM message to the maintenance software. When 
the Blue alarm is confirmed, the maintenance software places all trunks of the 
DS1 Interface circuit pack into the out-of-service state. The inquiry test will be run 
every 10 minutes until the Blue alarm is cleared.
The DS1 Interface circuit pack takes 2 seconds to recognize and report a Blue 
alarm and 16 seconds to recognize and report the resolution of a Blue alarm. 
When the Blue alarm is cleared, the DS1 Interface circuit pack stops transmitting 
the Yellow alarm and places the trunks back into the service state before the Blue 
alarm occurs.
 
PASS
DS1 signal is present and the physical link is healthy. In addition, no 
Integrated CSU errors are detected.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add ds1 
PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the link between the internal ID and the port.
Table 10-150.
TEST #138 Loss of Signal Alarm Inquiry Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page