Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-557
DS1-BD (DS1 Interface Circuit Pack) 
10
Yellow Alarm Inquiry Test (#141)
Receiving a Yellow alarm from remote DS1 endpoint indicates that the remote 
DS1 endpoint has an out-of-frame condition. The Yellow Alarm Inquiry Test is 
used to determine whether the remote DS1 endpoint is transmitting a Yellow 
alarm. The DS1 Interface circuit pack takes 500 msec to recognize and report a 
Yellow alarm and 500 msec to recognize and report that a Yellow alarm condition 
is cleared.
When the DS1 Interface circuit pack detects a Yellow alarm from the remote DS1 
endpoint, it will send a YELLOW-ALARM uplink message to the maintenance 
software. After the maintenance software receives the YELLOW-ALARM 
message, the Yellow Alarm Inquiry Test is run to confirm the Yellow alarm. Once 
the Yellow alarm is confirmed, the maintenance software places all trunks on the 
circuit pack into the out-of-service state. The Inquiry Test will be run every 10 
minutes until the Yellow alarm is cleared.
When the Yellow alarm is cleared, the maintenance software restores all trunks 
on the DS1 Interface circuit pack back to their previous service state before the 
Yellow alarm is raised.
This Yellow Alarm corresponds to the yellow F2 state documented in CCITT 
recommendation I.431.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add ds1 
PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout 
board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal ID and the port.
Table 10-152.
TEST #140 Red Alarm Inquiry Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page