Maintenance Object Repair Procedures 
Page 10-564
DS1-BD (DS1 Interface Circuit Pack) 
10
Slip Alarm Inquiry Test (144)
Slips occur when transmitter and receiver are not running at precisely the same 
clock rate. The DS1 Interface circuit pack can detect both positive and negative 
slips on the DS1 facility. The Slip Alarm Inquiry Test is used to acquire the total 
number of slips occurred on a DS1 link.
 
FAIL
The DS1 Interface circuit pack detects a Minor alarm. The DS1 bit error rate 
is greater than 1/1,000,000 and less than 1/1000.
1. The performance of DS1 link between DS1 Interface circuit pack and 
remote DS1 endpoint is poor. If DS1 Interface circuit pack is TN767, 
enter 
list measurement ds1-log PCSS
 command to read the error 
seconds measurement.
2. Verify that both endpoints of the DS1 link are administered using the 
same signaling mode, framing mode, and line coding.
3. If the DS1 interface circuit pack connects to a T1 facility, call the vendor 
of the T1 carrier to diagnose the remote DS1 endpoint. If the 
DS1interface circuit pack connects directly to a switch, call the system 
technician of the remote switch to diagnose the DS1 endpoint.
4. Check the physical connection of the DS1 pack and of the cable.
5. Replace the local DS1 interface circuit pack, and repeat the test.
 
PASS
No Minor alarm is detected in DS1 Interface circuit pack.
0
NO BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add ds1 
PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the link between the internal ID and the port.
Table 10-155.
TEST #143 Minor Alarm Inquiry Test  — 
Continued
Error 
Code
Test Result
Description/ Recommendation
Continued on next page