Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-567
DS1-BD (DS1 Interface Circuit Pack) 
10
Misframe Alarm Inquiry Test (#145)
Misframe Alarm indicates that framing bits observed on a DS1 Interface circuit 
pack are in error. Misframe Alarm Inquiry Test queries the total number of 
misframes that occurred on a DS1 Interface circuit pack since the last inquiry.
When the DS1 Interface circuit pack detects a misframe error, it will increase its 
misframe counter by 1. If the counter reaches the threshold, a 
MISFRAME-COUNT message is automatically sent to the switch maintenance 
software. After the maintenance software receives the MISFRAME-COUNT 
message, the Misframe Alarm Inquiry Test is initiated to collect the misframe 
counts from the DS1 Interface circuit pack.
When the threshold of misframes is reached, if the DS1 Interface circuit pack is 
supplying the system synchronization source, then a switching synchronization 
source message is sent to the TDM Bus Clock. See TDM-BUS (TDM Bus) 
Maintenance documentation for details. A Minor alarm against the DS1 Interface 
circuit pack is raised, but all trunks of the DS1 Interface circuit pack are still in the 
in-service state.
Table 10-157.
TEST #145 Misframe Alarm Inquiry Test 
Error 
Code
Test Result
Description/ Recommendation
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page