Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-574
DS1-BD (DS1 Interface Circuit Pack) 
10
CSU Equipment Loopback Test (#1210)
This test is destructive.
The CSU Equipment Loopback (ELB) Test causes a loopback at the near-edge 
of the local 120A CSU Module and tests the connection from the TN767E DS1 
board to the CSU Module (DS1 board edge interconnecting cable, and CSU 
Module edge). This test will only be performed if the 120A CSU Module is 
present, administered, and connected to a 1.544Mbps TN767E DS1 circuit pack 
on the back of the port carrier.
The test is destructive and can only be initiated by a system technician 
demanded 
test ds1-loop PCSS ds1/csu-loopback-tests
 command. 
All trunks or ports on the DS1 Interface circuit pack must be busied out via the 
system technician 
busyout board
 command before running the ELB Test.
When the ELB Test is initiated, maintenance software sends an appropriate 
message to the TN767E DS1 Interface circuit pack to start the test. The board 
sets up the ELB loopback, transmit a test pattern, and verify that the pattern is 
received unaltered through the loopback. If the transmitted and received pattern 
is different, the test fails.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add ds1 
PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout 
board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the link between the internal ID and the port.
Table 10-159.
TEST #1209 DS1 Board Loopback Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page