DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-577
DS1-BD (DS1 Interface Circuit Pack) 
10
CSU Repeater Loopback Test (#1211)
This test is destructive.
The CSU Repeater Loopback (RLB) Test causes a loopback at the far-edge of 
the local 120A CSU Module and tests the connection from the TN767E DS1 
board to and including the CSU Module circuitry. This test will only be performed 
 
FAIL
DS1 Interface circuit pack failed the CSU Equipment Loopback Test.
1. Retry 
test ds1-loop PCSS ds1/csu-loopback-tests
.
2. If the ELB test continues to fail, then either the TN767E board, the CSU 
Module, or the I/O cable between the backplane and the CSU module (or 
any combination thereof) has failed. Attempt to isolate the problem to one of 
these areas. Replace the CSU Module and running 
test ds1-loop PCSS 
ds1/csu-loopback-tests
 again.
3. If the ELB test continues to fail, then replace the TN767E board and run 
test 
ds1-loop PCSS ds1/csu-loopback-tests
 again.
4. If the ELB test continues to fail, the problem could be in the I/O cable 
between the backplane and the CSU module.
 
PASS
The ELB test executed successfully. The test pattern was transmitted and 
received successfully over the connection from the TN767E DS1 board to the 
near-edge of the 120A1 CSU Module.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add ds1 
PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout 
board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the link between the internal ID and the port.
Table 10-160.
TEST #1210 CSU Equipment Loopback Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page