Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-581
DS1-BD (DS1 Interface Circuit Pack) 
10
CPE Loopback Jack Test (#1212)
This test is destructive.
The CPE Loopback Jack (CLJ-LB) Test causes a loopback at the CPE Loopback 
Jack and tests the building wiring connection between the TN767E DS1 board 
and the CPE Loopback Jack.
The test is highly destructive and can only be initiated by a system technician 
demanded 
test ds1-loop PCSS cpe-loopback-jack-test-begin 
[number-of-bits bit-pattern]
 command. The System technician has the choice 
of entering a loopback activation code on the command line or using the default 
code (0x47F).
All trunks or ports on the DS1 Interface circuit pack must be busied out via the 
system technician 
busyout board
 command before running the CPE Loopback 
Jack Test.
The CPE Loopback Jack Test has the TN767E DS1 Interface circuit pack transmit 
a loopback activation code to the CPE Loopback Jack, waits up to 10 seconds 
for return of the code to verify the loopback has been established, transmits a 
framed 3-in-24 test pattern, begins counting bit errors in the received test 
pattern, and returns a PASS result to indicate that the pattern was successfully 
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add ds1 
PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the link between the internal ID and the port.
Table 10-161.
TEST #1211 CSU Repeater Loopback Test — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page