DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-607
DUPINT (Duplication Interface Circuit Pack) 
10
DUPINT (Duplication Interface Circuit 
Pack)
In a High or Critical Reliability PPN system, there are two Duplication Interface 
circuit packs: one in carrier A and one in carrier B. Together, Duplication 
Interface circuit pack A and Duplication Interface circuit pack B provide memory 
shadowing (see “SHDW-CIR” for a full description) and communication between 
software on the Active and Standby SPEs. By itself, Duplication Interface circuit 
pack A provides control of the duplicated Processor circuit pack, environmental 
maintenance monitoring and control, and administration terminal connection.
Duplication Interface circuit pack A controls a lead that lets the Tone-Clock 
circuit packs know which of them is supposed to be active and additional leads 
that control which SPE is active. The system software can request that either the 
SPE Select lead or Tone-Clock lead be changed.
Duplication Interface circuit pack A controls and monitors the same environment 
leads that the Maintenance/Tape Processor does in a PPN a system without High 
or Critical Reliability. Duplication Interface circuit pack A also supports the serial 
channel to the PPN administration terminal in a high or critical reliability PPN. The 
administration terminal connects to Duplication Interface circuit pack A via a 
connector on the back of carrier A labeled DOT. At any time, the administration 
terminal may be disconnected from Duplication Interface circuit pack A and 
connected directly to the active Maintenance/Tape Processor by attaching the 
administration terminal to the connector marked TERM on the active carrier. This 
connection should only be made if the administration terminal fails to function 
since a problem with the Duplication Interface circuit pack A may be present. 
The Duplication Interface circuit packs communicate over the Inter-Carrier Cable 
(ICC). The ICC connects the Duplication Interface circuit packs via pin fields on 
the backplane. The ICC consists of two 25-pin connector cables known as ICC-A 
and ICC-B. (
Note:
 A single-carrier cabinet system has an ICC-C also.) The pin 
fields where ICC-A and ICC-B connect are clearly labeled on the backplane near 
the pin fields for the Duplication Interface circuit packs. The ICC carries several 
important leads related to maintaining a high or critical reliability system.
1.
Alarms on Duplication Interface circuit pack in the A carrier are always major alarms and alarms 
on Duplication Interface circuit pack in the B carrier are always warning alarms. Determine the 
carrier to test via the PORT field from the Alarm or Error Log.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
Full Name of MO
DUPINT
MAJOR
test duplication 1C
Duplication Interface Circuit Pack
DUPINT
WARNING
test duplication 1C
Duplication Interface Circuit Pack