Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-618
DUPINT (Duplication Interface Circuit Pack) 
10
Duplication Interface Circuit Pack SPE A Loop 
Back Test (#275)
This test loops data back through the UART used to communicate with 
Maintenance/Tape Processor A. The data is generated by the Duplication 
Interface circuit pack processor and is looped through the UART. The test is 
done entirely on the Duplication Interface circuit pack. The test passes if the data 
sent matches the data received. This test does not check the physical serial 
channel that is printed on the backplane or carried by the ICC.
Table 10-175.
TEST #275 Duplication Interface Circuit Pack SPE A Loop Back Test 
Error 
Code
Test 
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The tested UART on the Duplication Interface circuit pack is defective.
1. If this is Duplication Interface circuit pack A, then the circuit pack must 
be replaced to restore duplication. If this is Duplication Interface 
circuit pack B, then this failure has no real impact on the system. 
However, since this Duplication Interface circuit pack can never be 
used in the A carrier, it should be replaced at some point.
2. Follow general procedures for replacing Common Control circuit 
packs, and replace the Duplication Interface circuit pack.
3. Rerun the test.
NO 
BOARD
The Duplication Interface circuit pack has failed to handshake with either 
the active Maintenance/Tape Processor (in the case of Duplication 
Interface circuit pack A) or the Duplication Interface circuit pack A (in the 
case of Duplication Interface circuit pack B).
1. Refer to NO BOARD description for the Duplication Interface Circuit 
Pack Status Query Test (#315).
PASS
The SPE A UART on the Duplication Interface circuit pack is good. This 
implies that Duplication Interface circuit pack A should be able to 
communicate with SPE A. This implies that Duplication Interface circuit 
pack B has a good UART.
Continued on next page