Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-627
E-DIG-STA (Emulated Digital Line) 
10
E-DIG-STA (Emulated Digital Line)
There are 4 tests in the Emulated Digital Line station maintenance test sequence 
and only one test path in the test sequence. Once the test sequence is started, 
all tests in the test sequence are executed.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack 
and the hardware connected to those ports for lines administered as a digital 
station. These include stations with an emulated digital voice terminal and 
stations with an emulated digital voice terminal and a linked data module. 
Stand-alone data modules and data adaptors in stand-alone mode are not 
supported by the TN800 circuit pack. Circuit pack maintenance is covered by 
E-DIG-BD.
Hardware Error Log Entries and
Test to Clear Values
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (for example, A, B, C, or D); and SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02, ...).
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
1
Full Name of MO
E-DIG-STA
MINOR
test port PCSSpp l
Emulated Digital St.
E-DIG-STA
WARNING
test port PCSSpp sh
Emulated Digital St.
Table 10-180.
Digital Line Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
18 (a)
0
busyout port PCSSpp
WNG
OFF
rel port PCSSpp
130 (b)
None
WNG
ON
test port PCSSpp sh
1793 (c)
Voice and Control Local 
Loop Test (#13)
MIN/ 
WNG
2
ON
test port PCSSpp l r 3
2049 (d)
NPE Crosstalk Test (#9)
MIN/ 
WNG
2
ON
test port PCSSpp l r 3
2305 (e)
32770
None
Continued on next page