DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-650
ETR-PT (Enhanced Tone Receiver Port) 
10
Tone Detector Audit/Update Test (#43)
A Digital Signal Processor sanity audit is performed on the ETR-PT.
102
FAIL
2225 Hz Modem Answer Tone was not detected 
correctly. This will impact call-classification operation.
1. Run the short test sequence via the 
test port
 
PCSSpp sh r 1 command. 
2. If the problem persists, the system can still operate 
properly but capacity will be reduced. In order to 
restore performance to normal, replace the circuit 
pack containing the defective port. Follow the 
procedures described in the TONE-BD section for 
replacing a tone/clock circuit pack.
130
FAIL
Forward or Backward MFC signals were not correctly 
generated or detected. This will impact MFC calls.
1. Run the short test sequence via the 
test port
 
PCSSpp sh r 1 command.
2. If the problem persists, the system can still operate 
properly but capacity will be reduced. In order to 
restore performance to normal, replace the TN2182 
circuit pack containing the defective ETR-PT. Follow 
the procedures described in the TONE-BD section 
for replacing a tone/clock circuit pack.
PASS
Tone Detection Verification is successful. The ETR Port 
is able to detect/generate all necessary tones.
Table 10-187.
TEST #42 Tone Detection Verification Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation