Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-689
EXP-INTF (Expansion Interface Circuit Pack) 
10
Expansion Interface Reset Test (#336)
FAIL
The Expansion Interface circuit pack responded incorrectly or, if it is 
the EPN Active Expansion Interface circuit pack, it could not talk to 
EPN circuit packs.
1. If the Active Expansion Interface circuit pack in the EPN is failing 
and a Standby link exists, switch to the Standby link using the 
set 
expansion-link PCSS
 command.
2. Repeat the Short Test Sequence.
3. If test continues to fail, reset the Expansion Interface circuit pack 
via the 
reset board PCSS
 command.
4. If the Expansion Interface circuit pack in the EPN is failing, check 
for EPN TDM-CLK, TONE-BD, or SYNC failures in the Hardware 
Error Log. Clear any EPN clock-related failures and repeat the 
Short Test Sequence.
5. If test continues to fail, replace the circuit pack or transceiver.
PASS
The Expansion Interface circuit pack did respond correctly to the test. 
Communication from software to the Expansion Interface circuit pack 
is functioning.
1. Refer to other Expansion Interface circuit pack tests if Expansion 
Interface Link is not functioning correctly.
0
NO 
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 
131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, 
check for hyperactivity (error 1538). If hyperactive, use the 
reset 
board PCSS 
command.
3. Run the test again. If it fails, the ID chip on board may be bad. 
Replace the board and retest.
Table 10-196.
TEST #316 Expansion Interface 
Control Channel Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page