Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-779
ISDN-PLK (ISDN-PRI Signaling Link Port) 
10
ISDN-PLK (ISDN-PRI Signaling Link 
Port) 
NOTE:
Use this Maintenance Object (ISDN-PLK) for maintenance tests, alarms, 
and hardware errors when the “ISDN-PRI over PACCON” option on the 
system-parameters customer 
form is set to a “
y
” When the ISDN PRI over 
PACCON is set to “
n
” use Maintenance Object ISDN-LNK.
The ISDN-PRI over PACCON option allows the PRI Links to be carried over the 
PACCON (Packet Controller TN778 circuit board), increasing the system 
ISDN-PRI capacity to the possible number of D-channels. An ISDN-PRI Signaling 
Link is known as a D-channel. The D-channel is used to transmit call-control 
signaling for the B-channels. B-channels (User information channels) are known 
as bearer channels (B-channels for example, transmit digitized voice, digital 
data); DS1 ISDN Trunks are B-channels and they carry the user traffic. PRI 
endpoint ports are also B-channels that can carry Wideband traffic. The call 
control signaling for the B-channels is combined and carried over the separate 
ISDN-PRI Signaling Link Port D-channel.
The ISDN-PRI Signaling Link Port is the port on a TN464C or later UDS1 Interface 
circuit pack that carries D-channel messages to the processor. The ISDN-PRI 
interface uses out-of-band signaling as opposed to robbed-bit, in-band 
signaling. For G3s, and G3i, this port can be used as an interface to the TDM bus 
or to the Packet bus. This is controlled by the “ISDN-PRI over PACCON” option. 
When the option is set to “
y
” the ISDN-PRI D-channel messages are transmitted 
over the Packet bus to the Packet Control circuit pack. The associated 
maintenance object name of the UDS1 port used to carry the D-channel over the 
Packet Bus is ISDN-PLK.
The B-channels associated with a ISDN-PRI D-channel can use ports on the 
same circuit pack or ports on other TN464C or later or TN767 DS1 Interface 
circuit packs (the TN722 cannot be used for this application). 
The TN767 DS1 interfaces is used for 24 channel 1.544 Mbps systems. The 
TN464C or later can be used for either 24 or 32 channel systems. The 32-channel 
1.
Where ’pp’ is ’24’ for 24-channel interfaces, and ’16’ for 32-channel interfaces.
2.
For additional repair information, see also PKT-CTRL (Packet Control), DS1-BD (DS1 Interface 
Circuit Pack) or UDS1-BD (Universal DS1 Interface Circuit Pack).
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
1
Full Name of MO
ISDN-PLK
2
MINOR
test port PCSSpp l
ISDN-PRI Signaling Link Port
ISDN-PLK
WARNING
test port PCSSpp sh
ISDN-PRI Signaling Link Port