Maintenance Object Repair Procedures
Page 10-810
ISDN-SGR (ISDN-PRI Signaling Group)
10
Remote Layer 3 Query (#637)
This test will query the far-end switch or terminal adapter to determine if the
signaling connection is functioning properly at Layer 3. It will select a B-channel
in the in-service or maintenance service state and send an ISDN Layer 3
SERVice message, which requires a response from the far end (similar to
performing Test #256 on an ISDN trunk. The test will not be performed if there are
no B-channels in an appropriate ISDN service state (as when none are
administered or they are all out of service).
signaling connection is functioning properly at Layer 3. It will select a B-channel
in the in-service or maintenance service state and send an ISDN Layer 3
SERVice message, which requires a response from the far end (similar to
performing Test #256 on an ISDN trunk. The test will not be performed if there are
no B-channels in an appropriate ISDN service state (as when none are
administered or they are all out of service).
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this
D-channel port is detached from the circuit pack. This is a normal
abort when the rollabout video feature is enabled. To complete test
on this port, either:
D-channel port is detached from the circuit pack. This is a normal
abort when the rollabout video feature is enabled. To complete test
on this port, either:
1. Re-attach the disconnected PRI terminal adapter and retry test
command, or
2. Disable the rollabout video feature on this circuit pack by
entering
change ds1 PCSS
and set the field
"Alarm when PRI
Endpoint Detached?"
to
"y"
.
4
FAIL
There is a problem with the Processor Interface Link. No DS1 ISDN
Trunk (B-channel) or wideband PRI Endpoint calls can be made
until the problem is resolved.
Trunk (B-channel) or wideband PRI Endpoint calls can be made
until the problem is resolved.
1. Display the Communication-Interface Links Form via the to
determine which link is down (find the one that matches the DS1
interface circuit pack this ISDN-PRI Signaling Link Port is on)
and then consult the procedures for Processor Interface Link.
interface circuit pack this ISDN-PRI Signaling Link Port is on)
and then consult the procedures for Processor Interface Link.
8
FAIL
There is a problem with the DS1/UDS1 Circuit Pack, or the
ISDN-PRI Signaling Channel (D-channel). No DS1 ISDN Trunk
(B-channel) or wideband PRI Endpoint calls can be made until the
problem is resolved.
ISDN-PRI Signaling Channel (D-channel). No DS1 ISDN Trunk
(B-channel) or wideband PRI Endpoint calls can be made until the
problem is resolved.
1. Consult the procedures for DS1/UDS1 Circuit Pack and the
ISDN-PRI Signaling Channel (ISDN-LNK/ISDN-PLK).
PASS
The basic physical connectivity of the primary D-channel is intact
and functional. Try this test repeatedly to ensure the link is up and
to uncover any transitory problems.
and functional. Try this test repeatedly to ensure the link is up and
to uncover any transitory problems.
Table 10-224.
TEST #636 Primary Signaling Link Hardware Check —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page