Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-850
MAINT (EPN Maintenance Circuit Pack) 
10
MAINT (EPN Maintenance Circuit 
Pack)
The EPN Maintenance circuit pack monitors and supports environmental 
maintenance for the EPNs. The EPN Maintenance circuit pack provides the 
switch software, a mechanism to enable and disable Emergency Transfer in the 
EPN (assuming the Emergency Transfer Switch is in the AUTO position). The 
EPN Maintenance circuit pack invokes Emergency Transfer when the EPN loses 
contact with the PPN or the EPN Maintenance circuit pack loses contact with all 
Expansion Interface circuit packs. When AC power fails in the EPN cabinet, no 
power holdover is available. If an Expansion Interface circuit pack goes insane 
and is reset six times within 15 minutes, the EPN Maintenance circuit pack holds 
the Expansion Links reset (which prevents the Expansion Interface circuit pack 
from running).
The EPN Maintenance circuit pack provides system level alarm LEDs which 
indicate the absence or presence of Major, Minor, and Warning alarms within the 
entire system (PPN and EPN).
The EPN Maintenance circuit pack supports a G3MT terminal which runs at 9600 
baud. However, the system software throttles the rate of data flow to the EPN 
Maintenance circuit pack for display on the terminal to about 1200 baud. All 
system commands can be executed via the EPN terminal. However, due to the 
slow speed at which the software runs the terminal, it is recommended that the 
EPN terminal’s primary use be for system maintenance rather than system 
administration.
The PPN communicates with the EPN Maintenance circuit pack using the 
following path (messages from the EPN Maintenance circuit pack to the PPN take 
exactly the reverse path). From the PPN, TN773 Processor circuit pack, EPN 
Maintenance circuit pack messages are passed to the Switch Control on the 
Network Control circuit pack over the Memory Bus (MBUS) and then over the 
TDM Bus to the Active PPN Expansion Interface circuit pack. The Active PPN 
Expansion Interface circuit pack passes the message across the fiber to the 
Active EPN Expansion Interface circuit pack. The Active EPN Expansion 
Interface circuit pack then passes the message over a serial link to the EPN 
Maintenance circuit pack. 
 illustrates this path.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
MAINT
MINOR
test maintenance sh
EPN Maintenance Circuit Pack
MAINT
MAJOR
test maintenance l
EPN Maintenance Circuit Pack