Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-854
MAINT (EPN Maintenance Circuit Pack) 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Sanity Handshake Test,
 for example, you may 
also clear errors generated from other tests in the testing sequence.
Note:
a. If you are invoking the Long Test Sequence from the EPN terminal, Test 
#104 causes the system technician terminal to be logged off, and Test 
#306 is not run as part of the test sequence. Test #104, however, causes 
Test #306 to run in an attempt to bring the EPN Maintenance circuit pack 
back to a known state. After the test sequence runs, the Error Log should 
be examined for MAINT errors of type 1 and 3073 to determine if the 
Network Control Circuit Pack DPR Test and EPN Maintenance Circuit Pack 
Reset Test failed.
If you are invoking the Long Test Sequence from the PPN, all tests listed 
are run and their results are displayed on the PPN terminal. The EPN 
terminal is still logged off.
Network Control Circuit Pack Dual Port Ram 
(DPR) Test (#104)
This test is destructive.
When executed, this test drops the EPN Manager I (G1) or G3MT terminal login. 
The login prompt reappears if the test passes successfully.
The Dual Port Ram (RAM), memory shared by the TN777 Processor circuit pack 
and the Network Control circuit pack, is tested to ensure that it can be read from 
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Sanity Handshake Test (#106)
X
X
ND
Network Control Circuit Pack DPR Test (#104) (a)
X
D
EPN Maintenance Circuit Pack Reset Test (#306)
X
D
Serial Channel Local Loop Around Test (#229)
X
X
ND
MGR I Channel Local Loop Around Test (#228)
X
D
EPN Maintenance Circuit Pack Sanity Maze Test (#303)
X
X
ND
EPN Maintenance Circuit Pack Serial Link Test (#337)
X
X
ND